As the temperature is getting higher and higher, the hidden dangers of household flammable gas are becoming more and more worrying. At this time, the gas detector plays a big role, but what should we pay attention to during normal installation!
The gas detector system consists of the controller of the monitoring room and the gas detector at the inspection site. The correct installation of these two parts can ensure the normal use of the gas alarm system.
First, the installation specifications of gas detectors:
1. The gas detector should use a relatively clean power source.
2. The gas detector should be installed in a non-explosion-proof place.
3. The outer casing of the gas detector needs to be grounded or the ground of the power plug is grounded.
4. The outer casing of the gas detector is strictly prohibited from being damaged, otherwise it will affect its shielding effect against static electricity.
5. Regardless of the installation method, the gas detector should be securely fixed to avoid vibration, dust and water. The environment should meet the requirements of the instrument manual.
Second, gas detector installation precautions
1. The gas detector should be within the range of 1 meter around the valve, pipe interface, air outlet or leaky area, as close as possible, while avoiding high temperature and high humidity environment, and not exceeding the temperature range and humidity range of the detector. Avoid external influences such as splashing water, oil and the possibility of mechanical damage.
2. There are various installation methods for gas detectors. It can be installed by ceiling or wall mounting. It should be ensured that the installation is firm and reliable, and the maintenance of the detector should be considered.
3. When the gas detector is installed, the sensor should be fixed downward.
4. The gas detector should be wired under the condition of power failure to ensure that the wiring is correct and then energized.
5. It is strictly forbidden to use the open flame test when testing the gas detector, so as to avoid premature failure of the probe due to excessive concentration of flammable smoke test, and it is strictly forbidden to test frequently.
Careful installation according to the detector specifications can make the detection results more accurate and more conducive to product life.
Chiller is a kind of water cooling equipment, is able to provide constant temperature, constant current, constant pressure cooling equipment. Cold water machine the principle is to a certain amount of water injection machine of the internal water tank, through the mechanism of cold water cooling system will be water cooling, and then have the machine within the cryogenic frozen water injection pump need to cooling equipment, cold water machine the internal heat away, the high temperature cooling of the hot water back into the water again, so exchange cooling cycle, as the function of the cooling equipment.