Power Transformer Six sampling Channels on Load Tap Changer Parameters Tester

Model NO.: ZXYZ-JZ
Trademark: GDZX
Origin: China
HS Code: 9030820000
 
Transformer Tap Changer Tester is an ideal device for testing on load tap changer.
 
Features
 
1. AC/DC method to test the true transition waveform ( No Filtering processing), suitable for on site test
of parameters like transition waveform, transition time, transient resistance and three-phase synchronization. 

2. It is easy to judge the on load tap changer when use AC test method. If the total transition waveform is
continuous then the working condition is good

3. Can test 10kV~500kV voltage no matter what kind of winding wiring ways.

4. Built in power supply or external connecting power supply. Built in type can output three phase power with
simple wire connection, external power supply can test high voltage test, zero sequence test

5. High speed sampling: over 200k/s/channel ( usually DC method speed is 10k/s). Large storage capacity, cache
depth up to 8M byte FIFO.

6. With embedded computer and testing software, 10.4" color lCD, touch screen, printer, supporting U disk and
USB keyboard and mouse

7. Meet the request of intelligent power grid operation and management system. The on-site operator can connect
the sampler with tablet PC and transmit data via internet

8. Can transmit and export the data to office PC for further analysis or editing off line

9. Can work as a digital multimeter

10. Integrated structure, portable, simple wire connection
 
Power Transformer Six sampling Channels on Load Tap Changer Parameters Tester
Parameters
 
1. Working condition:
 1)environment temperature: -10ºC~40ºC
 2)environment humidity: ≤80%
 3)altitude: ≤2000m

2. Power supply
 1)Single phase voltage: 220(1±10%)V
 2)Frequency: 50Hz±1Hz
 3)Waveform: sine wave, distortion≤2%

3. Internal output testing power:
 1)AC output frequency: 50Hz±0.2Hz(adjustable)
 2)AC output voltage range: 3P4W 0~500V( voltage adjustable)
 3)AC output capacity: rating 1000VA
 4)AC power source waveform distortion factor:≤3%
 5)AC current voltage phase angle: 120°angle difference≯120°±1°
 6)DC output current range 0.5A,1A for option

4,Accuracy
1)Synchronous sampling channels: 6
 2)Sampling data accuracy: 16 digits
 3)Sampling speed: 200 k/s/channel
 4)Sampling panel caching depth: 8 M byte FIFO
 5)Voltage range: 0V~500V
 6)Current range: 0mA~100mA,0A~10A
 7)Voltage current accuracy: 0.2
 8)Resistance range: 0.5A: 0-20Ω, 1A: 0-10Ω(can be customized)
 9)DC resistance accuracy: ±(5%+0.1Ω)

5,Insulation
 1)Insulation resistance: power supply input terminal to case >20MΩ
 2)It can withstand 1500V AC voltage (RMS)

6,Weight and volume:
 1)Weight: 30kg (exclude accessories)
 2)Dimension: 530*320*600(mm)

Power Transformer Six sampling Channels on Load Tap Changer Parameters Tester
Power Transformer Six sampling Channels on Load Tap Changer Parameters Tester


 

Open Cooling Tower