Instructions and maintenance for various light incubators

Light incubator | Thermostatic light incubator | Smart light incubator Instructions for use: 1, turn on the power, close the power switch, the whole power, the switch power indicator light.

2. Please refer to the manual of intelligent digital temperature controller for temperature control setting.

3, if you need to turn on the lighting switch.

Light incubator | Thermostatic light incubator | Intelligent light incubator maintenance and culture:

1. The incubator housing should be reliably grounded.

2. Incubator should be placed in a cool, dry, well ventilated place away from heat and sunlight. Keep it stable to prevent vibrations from generating noise.

3, in order to ensure that the condenser effectively cooling, the distance between the condenser and the wall should be greater than 100mm. There should be 50mm clearance on the side of the box, and there should be at least 300mm on the top of the box.

4. The incubator should avoid collisions and shake vibrations during handling, maintenance and maintenance; the maximum inclination is less than 45 degrees.

5, the instrument suddenly does not work, please check the fuse tube (after the box) is burned, check the power supply.

6. When the incubator is working in refrigeration, the difference between the temperature in the cabinet and the ambient temperature should not be greater than 25 degrees.

Light incubator | Thermostatic light incubator | Intelligent light incubator temperature control table Key functions 1, the number of period segment keys: click on the cycle number key to switch the display of the current operation cycle or number of segments, long press the key 2S to enter the cycle setting state, and then Press and hold for two seconds to exit.

2. Set query key: Click to enter the query status, you can query the current running number of segments, set time, set temperature and set humidity, and then click this key to exit. Long press this key 2S to enter the segment number selection state. After selecting the segment number, press the key again to enter each segment parameter setting state. In the setting state, press and hold the setting query key 2S again to exit each segment parameter setting state. (When the period is set to 0 and the first period of time is 0, the first program is always run;)

3. Decrease the key: When setting the parameter, click this key to decrease the value by one. Pressing this key for a long time will reduce the value continuously.

4, increase the key, in the setting of parameters, click the key to increase the value of the set, long press the key to set the value will increase continuously;

5. Back (back) key: In each parameter setting state, click this key to return to the previous parameter (you can only switch the parameters of the same paragraph). When the alarm buzzer sounds, press this key to silence. In the operation stop state, long press this key 4S can make the controller start again from the first stage.

6. Temperature parameter (temperature) key: Long press this key 2S to enter internal parameter state, click this key to set internal parameters, and press 2S again to exit.

7, lighting key: Click this key has a lighting box light.

8. Power button: Click this button to enable the controller to work or enter the closed state.

In each setting state, if no key is pressed within 30 seconds, the program will automatically exit to normal operation.

If you have any questions, please contact us: Jintan Guowang Experimental Instrument Factory Telephone Fax E-mail:

Website: http://

Chlorinated Polyethylene(CPE)

1. CPE is a kind of saturated rubber, which has excellent heat-resistant oxygen aging, ozone aging, acid and alkali resistance, and chemical resistance.


2. CPE has general oil resistance. Among them, it has excellent resistance to ASTM No. 1 oil and ASTM No. 2 oil, which is equivalent to NBR; and it has excellent resistance to ASTM No. 3 oil, which is better than CR and is equivalent to CSM.


3. CPE contains chlorine element, has excellent flame retardant performance, and has the characteristics of burning and dripping. It can be combined with antimony flame retardant, chlorinated paraffin, and Al(OH)3 in an appropriate ratio to obtain a flame retardant material with excellent flame retardancy and low cost.


4. CPE is non-toxic, does not contain heavy metals and PAHs, and it fully meets environmental protection requirements.


5. CPE has high filling performance and can be manufactured to meet various performance requirements. The processing performance of CPE is good, and the Mooney viscosity is available in a variety of grades between 50-100.


CPE 135A, Chemical Chlorinated Polyethylene,Modifier Chlorinated Polyethylene,Cpe Chlorinated Polyethylene

Henan Shunbang Chemical Industry CO.,Ltd , https://www.suspensionpvc.com