Model NO.: ZP88
Flow Direction: Bidirectional
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Diameter: Dn15~25mm
Pressure.: Pn0.6~1.6MPa
Temperature: 0-70degree Centigrade
Standard.: GB, DIN, ANSI, GOST, JIS, BS
Materials: Copper, Other Materials Are Customizable
Trademark: Tianjin U-ideal Instrument
Transport Package: Wooden Case or Carton
Specification: CE, ROHS, SGS, GMP
Origin: Tianjin, China
HS Code: 8481804090
Tianjin U-ideal Air Vent valve for Solar Water Heater, Air release valve with Check ValveAutomatic air vent valve in brass with silicone rubber plug
Automatically dispose of trapped air bubbles in a system
Includes manual venting outlet
Compact design to allow installation in applications with limited space
Applications for Tianjin U-ideal float-type air vents include hydronic heating systems, water service lines, water storage tanks, centrifugal pumps, gas lines, solvent filters and similar equipment. Operation is completely automatic, and the simple design and quality mechanism make operation trouble-free and maintenance infrequent.
These Air vent are compact float-type valves for the removal of air and other gases from hydronic heating and cooling systems, liquid chilling operations, and other light liquid services.
The Air vent valve is designed to release air-pockets out of the piping system.I t should be installed at every high-point of the piping system where air can be trapped. The simple construction relies on a float held by a lever,so that the float does not rub against the body to avoid any risk of jamming.
Why remove air from a water system?
Every building services engineer knows that air trapped in either a hot or chilled water system can cause
trouble, such as excessive noise, corrosion and increased maintenance costs. Air can cause air locks which inhibit the filling of the system or the priming of pumps. It can seriously affect the accuracy of flow measurement meters and regulating valves. Under extreme conditions it may even temporarily decommission plant.
Air and other incondensable gases considerably reduce heat transfer efficiency. A film of air 1 mm thick
presents the same barrier to heat transfer as a wall of copper 13 m thick!
Entrapped air in any water system is a threat to thermal efficiency. It is particularly damaging in a chilled water system which does not have the natural deaerating ability of hot water.
Â
Air Valves vs. HydrantsÂ
There is a common misconception that fire hydrants can be used in place of combination air valves to provide the required air-release service. This method should be strongly discouraged for several reasons:Â
The use of fire hydrants requires active user intervention, which creates a hidden maintenance cost. In order to be effective, the hydrants should be discharged once per day. At just five minutes per hydrant at a rate of $10.00 per hour, a small town with twenty hydrants would spend more on the labor used than it would have spent on twenty automatic air valves.Â
Manual air release cannot accommodate surges in flow or demand. Only automatic air valves can provide the needed functions on demand in order to protect the water system.Â
Hydrants cannot provide the vacuum-breaking function required to prevent contamination during negative-pressure events. Automatic air valves help protect the finished water at all hours, every day of the year.Â
The pressures accumulated within the hydrant, even at a system pressure of 80 psi, can be extremely hazardous to maintenance workers. Accumulated pressures in some systems can reach more than ten times the rated system water pressure. Automatic air valves work without user intervention and prevent the accumulation of pressure.Â
Hydrants are typically mounted to the sides of a main (at the 3 o'clock and 9 o'clock positions), rather than at the top. This can significantly reduce their effectiveness as air-release devices, even when flanged at the full diameter of the main. Automatic air valves are properly installed only at the top (12 o'clock) position, where they can provide complete discharge of accumulated air.Â
Combination air valves from Tianjin U-ideal are the most advanced sold anywhere in the world.Contact us for custom specifications and calculations by send e-mail , and we'll be happy to share more about them with you.
Â
Origin | Tianjin China |
Brand | Tianjin U-ideal Instrument |
Connection | Flange or thread |
Export Markets | Global |
Packing | Wooden Case or Carton |
About us | Our company is specialized in the manufacture of valves, ,flow meters,level gauges,etc |
Why Choose us | |
Rich experience | We have been engaged in machining for many years. Our company had good reputation with customers from American, Europe, North America, and Australia, India etc. We also have a good team for sale and quality control. |
Good service | We will respond to you within 24 hours. We manufacture non-standard parts according to your drawings. And we will continue to serve you after sales and will be responsible for the mistakes from us. |
Low price | The prices of our production are reasonable! The prices will be much better if your quantity is good. |
Perfect quality | We have strict quality control from producing to delivery. Our company had strong technology support, 80% of our colleagues are master or bachelor's degree. We have cultivated a group of managers who are familiar with product quality, good at modern concept of management. |
Contact | |
If you have any question or requirements, please don't hesitate to contact us. Tel: 86-22 88971536 Fax: 86-22 88971536 |
Plastic Dustbin,Large Plastic Dustbin,Plastic Dust Bins,Heavy Duty Plastic Dustbin
Jiangsu Ru Shun plastic industry Co., LTD , https://www.rushunsuye.com